Time clock on the left will turn “on” and “off” filter speed (1) and should be set to run approximately _____ hours every day
Do not use the filter speed (1) to add D.E. to the filter or to prime the pump
Time clock on the right will turn “on” and “off” cleaner speed (2) and should be set to run approximately ____ hours a day
Cleaner speed (2) time clock should always be set to turn “on” and “off” within the selected filter pump speed (1)which is set on left time clock (This speed is also used in filter cleaning and priming of the pump)
Left Side Switch Operation
The switches on the bottom left side of the time clock is for turning “on” and “off” spa speed (3) and auxiliary speed (4) if used
The upper switch is for manually operating the spa speed (3) and the lower switch is for manually operating auxiliary speed (4) if used
Right Side Switch Operation
The switch(s) on the bottom right side of the time clock is for turning “on” and “off” pool and spa lights if present
GFI Outlet
A GFI outlet is located outside the time clock enclosure on the right side.
If the pool and spa light do not turn on, press the “reset” button located on GFI outlet.
If the problem still exists check the circuit breaker labeled “Pool Light” located in the panel box